Table 1 Lower calorific value and composition of design waste
Item Low-calorific waste Design waste High-calorific waste
Lower calorific value 4187 kJ/kg 6699 kJ/kg 8374 kJ/kg
Moisture content 56.19 % 48.40 % 43.21 %
Combustible content 25.23 % 33.44 % 38.91 %
Ash content 18.58 % 18.16 % 17.88 %
Cl 0.27 % 0.32 % 0.35 %
S 0.09 % 0.11 % 0.12 %
Table 2 Specifications of units
Item Type, specification
Incinerator Ebara model HPCC*1 stoker-type incinerator
Treatment capacity:
Songjiang Plant: 2000 t/d (500 t/24 h× 4 lines)
Fengxian Plant: 1000 t/d (500 t/24 h× 2 lines)
Boiler*3 Natural circulation type water tube boiler with superheater
Evaporation amount:
Songjiang Plant: 47 t/h (max. 52 t/h)×4 boiler units
Fengxian Plant: 47 t/h (max. 52 t/h)×2 boiler units
Steam condition: 400 ℃×4.0 MPa (Gauge pressure, outlet of superheater
Steam turbine power generator*4 Steam turbine (condensing type) with power generator
Turbine rating:
18 MW×2 units (Songjiang Plant)
18 MW×1 unit (Fengxian Plant)
Power generator rating:
20 MW×2 units (Songjiang Plant)
20 MW×1 unit (Fengxian Plant)
Flue gas treatment equipment*3 Dust collection method: Bag filter
HCl and SOx removal method: Dry process (calcium hydroxide injection), wet process (caustic soda), GGH (gas-gas heat exchanger)
Denitration method: SNCR*2
Dioxins removal method: Activated carbon injection method
Stack External cylinder: Made of reinforced concrete; Internal cylinder: Made of steel
Height: 80 m
*1 HPCC: High Pressure Combustion Control
*2 SNCR: Selective Non Catalytic Reduction
*3 Undertaken by Ebara Group: Basic design; Undertaken by SPC: Purchase
*4 Undertaken by SPC: Basic design, purchase
Table 3 Flue gas standard values at the outlet of the stack
Item O211% equivalent value O212% equivalent value
Dust ≦10 mg/m3(NTP) ≦9 mg/m3(NTP)
Sulfur oxide SOx ≦50 mg/m3(NTP) ≦15.8 ppm
Nitrogen oxide NOx ≦200 mg/m3(NTP) ≦87.7 ppm
Hydrogen chloride HCl ≦10 mg/m3(NTP) ≦5.5 ppm
Carbon monoxide CO ≦50 mg/m3(NTP) ≦36.0 ppm
Dioxins ≦0.1 ng-TEQ/m3(NTP) ≦0.09 ng-TEQ/m3(NTP)
Table 4 Guaranteed items
Item Guaranteed item
Annual accumulating operating time 8000 hours or longer
Operation range (Load of amount of incineration) 60 to 110 %
However, the 110 % load is within 2 hours/day.
Temperature at outlet of incinerator 850 ℃ or over, for 2 seconds or longer
Ignition loss of ash 3 % or less
Boiler efficiency 80 % or over
Grate replacement rate Operating time
8000 hours Less than 4%
16000 hours Less than 11%
24000 hours Less than 15%
32000 hours Less than 18%
Consumption of chemicals by flue gas treatment equipment
*Design waste quality
Under 100 % load
Urea 0 kg/t (waste) or less
Caustic soda (30 %) 9.5 kg/t (waste) or less
Calcium hydroxide 8.8 kg/t (waste) or less
Activated carbon 0.58 kg/t (waste) or less
Table 5 Construction schedule
Item Songjiang plant Fengxian plant
Contract August 2013 August 2013
Installation of units September 2014 to April 2016 October 2014 to May 2016
Commissioning (waste incineration) May to October 2016 June to September 2016
Hand-over November 2016 October 2016
Table 6 Acid gas removal efficiency of the dry type flue gas treatment unit 1)
Item Value
Temperature of gas at the inlet of the flue gas cooler 175 ℃
Equivalent ratio of calcium hydroxide 1.2
HCl removal rate 71.5 %
SOx removal rate 48.1 %
Table 7 Relationship between pH and acid gas removal performance
Item Case 1 Case 2
pH adjustment range 6.0~6.5 6.7~7.1
HCl removal rate 97.1 % 97.3 %
SOx removal rate 84.7 % 89.7 %
Table 8 GGH operation data
Item Unit Design value Operation value
Amount of flue gas at the inlet of the GGH (high-temperature side) m3/h(NTP) 84700 79627
Temperature of flue gas at the inlet of the GGH (high-temperature side) 170 176
Temperature of flue gas at the inlet of the wet scrubber 111 116
Temperature of flue gas at the outlet of the wet scrubber 65 67
Temperature of flue gas at the inlet of the stack 125 126
Table 9 Performance test results of the incineration facility in Fengxian plant (100 % load)
No. Guaranteed item Unit Guaranteed value Incinerator No. 1 Incinerator No. 2 Judgment
1 Waste treatment capacity t/d ≧500.0 526.2 560.8 Passed
2 Boiler efficiency % ≧80.00 80.95 81.39 Passed
3 Flow rate of main steam t/h ≧47.00 48.29 47.62 Passed
4 Temperature of main steam 395~403 393.1*5 397.6 Passed
5 Pressure of main steam MPa 3.80~4.20 3.86 3.88 Passed
6 Ignition loss of ash % ≦3.00 1.95 1.76 Passed
7 Retention time of flue gas at 850 ℃ s ≧2.0 3.9 3.8 Passed
8 Lower calorific value of waste*6 kJ/kg 6699 6796.3 6357.6
9 Noise
Hydraulic unit dB(A) <85 79.4 79.7 Passed
10 Flue gas at outlet of stack (NTP, dry, O211%)
Dust mg/m3 ≦10 6.8 5.9 Passed
Hydrogen chloride mg/m3 ≦10 9.2 7.8 Passed
Hydrogen fluoride mg/m3 ≦1 0.3 0.2 Passed
Sulfur oxide mg/m3 ≦50 4.5 3 Passed
Nitrogen oxide mg/m3 ≦200 187.9 199.4 Passed
Carbon monoxide mg/m3 ≦50 5.3 5.9 Passed
TOC mg/m3 ≦10 0.4 0.4 Passed
Hg and compound mg/m3 ≦0.05 8E-05 3.7E-05 Passed
Cd and compound mg/m3 ≦0.05 Not detected Not detected Passed
Pb and compound mg/m3 ≦0.3 0.009 0.004 Passed
Other heavy metals mg/m3 ≦0.5 0.219 0.214 Passed
Blackness of flue gas Ringelmann ≦1 <1 <1 Passed
11 Consumption of chemicals by flue gas treatment equipment
Activated carbon kg/t of waste ≦0.58 0.46 0.44 Passed
Calcium hydroxide kg/t of waste ≦8.8 6.59 6.34 Passed
Caustic soda kg/t of waste ≦9.5 5.49 5.77 Passed
Urea water kg/t of waste 0 0 0 Passed
*5 The item was judged to have passed the test because the main steam did not reach the reference temperature for reasons on the SPC’s side.
*6 Pass/fail judgment is not made because it is not a guaranteed item.